Pants duct

HomeProducts Center

Pants duct

Pants duct

Other Names:

Introduction Pants duct Uses: used in coal mines, tunnels, underground local fan for positive pressure ventilation; Pants duct varieties: coated cloth duct by rubber coated cloth material into a positive pressure air duct, plastic-coated fabric and rubb

Related Products

Product Detail:

Product Introduction

 

Introduction

Pants duct Uses: used in coal mines, tunnels, underground local fan for positive pressure ventilation
Pants duct varieties: coated cloth duct by rubber coated cloth material into a positive pressure air duct, plastic-coated fabric and rubber coated cloth duct pressure pressure duct.
 
Pants duct wind pressure resistance resistance: Hair Dryers by wind pressure resistance test shall produce hairdryer disjointed, coated cloth torn seams opening and so on. Duct diameter shall not be greater than 3.0 percent expansion.
1, the wind pressure resistance test: the inner duct pressure reaches 5000 ~ 5100Pa, and keep 5min, observe whether the disjointed hairdryer, tear, opening seams and other anomalies;

2, swelling determination: in duct pressure-resistant measured at the same time, hairdryer circumference with a tape measure to calculate duct diameter expansion.

Packing and shipping store

1.Pants should be folded duct rings on the outside, with a woven bags.
2
Pants duct during transport to prevent mechanical impact and friction, avoid the sun and rain.
3
Pants duct should be stored in well-ventilated warehouse, stacking not too high, so as not to affect the use of quality, used duct, should first wash dry and then stored folded, prohibition and detrimental to the rubber and plastic quality material contact, avoid direct sunlight, rain, warehousing temperature should be between -15 ~ 35 , relative humidity between 45-75%, and not far from the heat source than 1m.
4
Pants duct within the specified transport, storage conditions, since the production date, shelf life 1 year of its flame retardant, antistatic meet the requirements of this standard.
5
Pants duct should be based on the size of the roadway and the fan flow to select the appropriate specifications and other requirements, as well as elbows, tees and other shaped specifications, flow direction when you connect.
6
Pants duct should be hung up in the roadway, so straight, taut hanging in prison, every ring will hang, see the bad will complement, turning slowly, excluding water, in order to facilitate reducing drag. (Patch Method: Wash the breakage dry, glue processing)

Product Feedback

Average Star Rating:

History Feedback: (0)

Latest Feedback

    Star Rating:
    Contacts: *
    EMail: *
    Message: *
    Verification code:          
     
     
    客服中心

    客户服务热线

    0537-7768777


    展开客服